Slider Image
Slider Thumb

  • 7" Color Touchscreen
  • Light Source - Halogen Lamp
  • Wavelength Range- 340nm-750nm, 4 Filter Wheel
  • Standard Filter - 405nm, 450nm, 492nm, 630nm
  • Filter Bandwidth- 8~10nm, Reading Range - 0~4.000Abs
  • Measuring Speed - 6Sec, 96 Hole Plate Deduction
  • Memory - 1000 Program, 1,00,000 Result

Credit Card,Netbanking

Slider Image
Slider Thumb

Credit Card,Netbanking

Key Attributes
Industry-specific Attributes
  • Wavelength selection Monochromator
  • Light source Xenon flash lamp
  • Wavelength range 200–1,000 nm with 1 nm steps
  • Readout range Up to 4 absorbance units
  • Bandwidth <2.5 nm
  • Linearity at 450 nm* 0–2.5 Abs, 2%
  • Accuracy at 450 nm* 1.0% + 0.003 Abs (0–2.0 Abs), 2.0% (2.0–2.5 Abs)
  • Precision at 450 nm* SD <0.003 Abs or CV <1.0%
  • Plates 6- to 48-, 96-, and 384-well plates***, Thermo Scientific µDrop Plates
  • Cuvette Dimensions (H x W x D): 40–58 x 12.5 x 12.5 mm Beam center height: 8.5 mm Beam window: ≥2 mm
Other Attributes
  • Measurement speed (starting from A1 back to A1) 6 sec with 96-well plate 10 sec with 384-well plate
  • Plate shaking Linear
  • Spectral scanning speed 10 sec from 200–1,000 nm with 1 nm steps
  • Incubation range From ambient temperature +2C to 45˚C”.
  • User interfaces Stand-alone use: 7 in. touchscreen display
  • Main input 100–240 V (50/60 Hz)
  • Max power consumption <110 W
  • Power save consumption** 7 W
  • Dimensions (H x W x D) 265 x 295 x 445 mm (10.4 x 11.6 x 17.5 in.)
  • Weight True weight: 10.6 – 11.5 kg (23.4 – 25.3 lb), depending on the model
Slider Image
Slider Thumb

Credit Card,Netbanking

Key Attributes
Industry-specific Attributes
  • Number of wash buffer bottles 1
  • Bottles 2 I wash bottle,2 I wash bottle
  • Plate types 96-well plates
  • Wash volume 50 – 1000 μl
  • Prime volume /Rising Volume 5-100 ml/-
  • Dispensing volume 50-400 μl
  • Residual Volume <2 μl
Other Attributes
  • Data Transfer USB port
  • Dispense precision < 3% (CV) @ 300 μl (96-well plate), with, 1 x 8 or 1 x 12 wash hand
  • Dispense accuracy <5% @ 300 μl with 1 x 8 or 1 x 12 wash head
  • Number of wash products Up to 99
  • Robot compatible No
  • Weight 8 kg (17.6 Ibs)
Slider Image
Slider Thumb

Credit Card,Netbanking

Slider Image
Slider Thumb

Credit Card,Netbanking

Slider Image
Slider Thumb

Credit Card,Netbanking

Key Attributes
Industry-specific Attributes
  • Buffer Volume 650ml
  • Number of casting Tray 15x7cm,15x10cm (1 No. Each)
  • Number of Combs 20 wells 1.5mm thickness comb (4 Nos.)
Other Attributes
  • Connecting Cord Red and Black (Each One)
  • No. of Platinum electrodes Positive and Negative (Each One)
  • Buffer Chamber with Safety Lid 1 No.
Slider Image
Slider Thumb

Credit Card,Netbanking

Key Attributes
Industry-specific Attributes
  • PRINCIPAL MATERIAL ACRYLIC
  • INNER TANK DIMENSIONS 145 X 145 X 60 mm
  • PAPER SUPPORTING ROD 3NOS
  • GLASS PLATES 50 X 50mm (12 Nos)
Other Attributes
  • NO. OF PLATINUM ELECTRODE RED AND BLACK (1 EACH)
  • CONNECTING CORD RED AND BLACK (1 EACH)
  • LID 1 NO
  • RECOMMENDED POWER SUPPLIES 12-02, 12-03
Slider Image
Slider Thumb

Credit Card,Netbanking

Key Attributes
Industry-specific Attributes
  • MAKE GENEI
  • MODEL MINI SUB SYSTEM
  • PI.NO 03-01
  • CAT NO. 106470GB
  • PRINCIPAL MATERIAL ACRYLIC
  • INNER TANK DIMENSION 190 X 80 X 55 mm No.of
  • TRAYS 100 X 70 mm-1 NO.
Other Attributes
  • NO.OF COMBS 8 WELL X 4 nos, 3 WELL PREPARATIVE
  • NO . OF GEL CASTING TRAY 1 UNIVERSAL
  • CONNECTING CORD 1SET (1 BLACK AND 1 RED )
  • NO . OF PLATINUM ELECTRODES 1 ANODE AND 1 CATHODE
  • LID 1NO
  • RECOMMENDED POWER SUPPLIES 12-01, 12-02, 10 - 01
Slider Image
Slider Thumb

Credit Card,Netbanking

Key Attributes
Industry-specific Attributes
  • Line regulation < 0.2%
  • Load regulation < 1% at load change 10-90% of maximum load
  • Ripple < 1% at 1000 V
  • Short term stability < 0.2% /10 h after warm up
  • Long term stability < 1% /year
  • Start current check Resistance not greater than 0.2 MW at 40 V
Other Attributes
  • Output protection Fully protected against any overload conditions
  • Ambient operating humidity 0-95%
  • Ambient operating pressure 84-106 kPa
  • Power consumption Max 140 W
  • Dimensions (WxDxH) 250 x 385 x 95 mm
  • Weight 3.8 kg
Slider Image
Slider Thumb

Credit Card,Netbanking

Key Attributes
Industry-specific Attributes
  • Mass range m/z 1.5 to 1,000
  • Measurable FWHM 0.5 to 2.0 u
Other Attributes
  • EI scan S/N 1 pg octafluoronaphthalene m/z 272 S/N ≥ 600 (helium gas)
  • High-speed scan rate 10,000 u/sec
Slider Image
Slider Thumb

Credit Card,Netbanking

Key Attributes
Industry-specific Attributes
  • Range 0.000 – 10.000 mL/min., in 0.001 mL/min increments,standard 100 µL heads
  • Flow Precision £ 0.1% RSD or two seconds SD, six replicates,based on rentention time or volumetric measures,at mL/min, 1,000 – 2000 psi backpressure Compressibility
  • Compensation Programmable
  • Flow Clibration Programmable
  • Function Pre Programmed, user intiated
  • Maximum Operating pressure 6,000 psi (41,370 kPa, 401 bar)
  • Operating Pressure Limits Programmable high and low pressure limits User selectable in psi,kPa, bar
  • Pressure Ripple £ 2.0 % (1 mL/min, degassed methanol, 1,000 psi backpressure)
Other Attributes
  • Plunger Guiding System Floating, self- aligning mount
  • System Floating, self-aligning mount
  • Primary Wetted Surface Materials 316 stainless steel, sapphire, reinforced fluorocarbon polymer seals.
  • Physical Size (W x H x D) 7.5” (19.1cm) x 8.0” (20.3) x 18.5” (47 cm)
  • Weight 33 Ib (15 kg)
  • Voltage range 85 to 264 VAC
  • Frequency 47 to 63 Hz, single phase
Slider Image
Slider Thumb

Credit Card,Netbanking

Key Attributes
Industry-specific Attributes
  • High throughput Designed for fast analysis with narrow bore capillary columns, reducing analysis time and improving sample throughput
  • Advanced flow Control Provides precise and reproducible carrier gas flow and pressure control, essential for accurate retention times and peak areas.
  • Maximum pressure 970 kPa
  • Maximum flow rate 1200 Ml/MIN. Constant linear velocity mode is supported.
  • High-Performance Oven Ambient + 40C to 4500C with (optional : -500c to 4500C with liquid CO2)
  • Dimensions 280 (W) x 280 (H) x 175 (D) mm
  • Volume 13.7 L
  • Temperature accuracy Set value + 1% (calibrated at 0.010C)
  • Temperature Deviation Maximum (on a 200 mm diameter)
  • Temperature Program Up to 20 ramps (heating & cooling possible), with a programmed rate setting range of -250 to 2500C/min and a maximum total time of 9999.99 minutes. Rapid heating and cooling capabilities are incorporated.
Other Attributes
  • Injection Units Up to two analytical lines can be installed, and various injection units are available.
  • Split/ Splitless Injector Standard configuration with high-performance AFC, supporting high-speed GC. Features a gas saver function and high-pressure injection mode.
  • Direct Injection Unit For wide –bore capillary columns (>0.45 mm), with a septum purge flow channel.
  • On-Column/Programmed Temperature Vaporizer (OCI/ PTV) Temperature programmable (room temperature + 50Cto 4500C),with heating rates up to 2500C/minute and cooling rates down to 500C in 8minutes.
  • Automation Compatible with the AOC – 20i Auto Injector and AOC-20s Autosampler, handling up to 150 vials for increased throughput. Dual injection systems can be configured.
  • User Interface Features a back-lit Lcd display for easy monitoring and control.
  • Software Gc solution software is compatible with windows and comprehensive instrument control, data acquisition, and analysis features, including various quantitation methods, calibration, and reporting.
  • Dimensions and Weight 515 (W) x 440 (H) x 530 (D) mm, approximately 30 kg (for a single FID model)
  • Power Requirements AC100V/115V/230V + 10%, 1800VA(normal oven) or 2600VA (high-power oven), 50/60Hz.